| MODEL | MP-LIONEX-DUAL 6KW |
|---|---|
| Rated power | 6000W |
| Nominal Battery System Voltage | 48V |
| PV INPUT(DC) | |
| Maximum recommended DC power | 9000W |
| Nominal DC operating voltage | 360V |
| Maximum DC voltage | 500V |
| MPPT voltage range | 120V~500V |
| Maximum input current | 15A / 15A |
| No.of MPP tracker | 2 |
| Strings per MPP tracker | 1 |
| INVERTER OUTPUT(AC) | |
| Nominal AC output power | 6000W |
| Nominal output voltage; range | 220/230/240V;180-280V |
| AC grid frequency; range | 50/60Hz; 45~55/55-65Hz |
| Nominal output current | 26A |
| Maximum output current | 27.2A |
| Inrush current (spike/duration) | 57.5A/5.2us |
| Total harmonic distortion i(THDi) | <3% |
| Power factor at rated power | 1 |
| Displacement power factor | 0.8leading~0.8lagging |
| Grid type | Single phase |
| BATTERY MODE OUTPUT(AC) | |
| Output Rated Power | 6000W |
| Nominal output voltage; accuracy range | 230±1% |
| Output ferequency; accuracy range | 50/60Hz (optional)±0.2% |
| Output rated current | 26A |
| Output waveform | Pure sine wave |
| Peak power | 9000W,10s |
| Total harmonic distortion v (linear load) | <3% |
| BATTERY & CHARGER | |
| Battery type | Lead-acid battery / Lithium battery |
| Battery voltage | 48V |
| Battery voltage range | 40~60V |
| Charging curve | 3-stage adaptive with maintenance |
| Protection | Over-current protection / Over-temperature protection |
| Maximum charging power | 6000W |
| Maximum charging currernt | 125A |
| EFFICIENCY | |
| 97.1% | |
| 96.5% | |
| 99.8% | |
| PROTECTION DEVICES | |
DC switch rating for each MPPT; Grid monitoring; Output over current protection; Output overvoltage protection-varistor; Ground fault monitoring; Integrated all-pole sensitive leakage current
| GENERAL | |
| Machine Dimension (W*H*D)(mm) | 480*420*215 |
| Package Dimension (W*H*D)(mm) | 610*327*595 |
| N.W(kg) | 30 |
| G.W(kg) | 32 |
| DC connection | H4 / MC4 |
| AC connection | Terminal Block |
| Display | LED+LCD |
| Communication interfaces | Wi-Fi / USB / GPRS / RS485 |
| Ingress protection rating | IP65 |
| Humidity | 0~95% RH(No codensing) |
| Operating temperature range | -20°C+60°C With derating above 45°C |
| Cooling concept | Natural |
| Altitude | <3000m |
To ensure peak performance and longevity, keep your unit in a clean, dry, and well-ventilated environment away from direct moisture and extreme heat sources. Regularly inspect terminal connections for security, clear any dust buildup from cooling vents or fans, and follow recommended operational guidelines to safeguard your investment.
Proper installation is crucial for safety and system efficiency. This equipment should always be mounted and wired by a qualified, certified solar technician in accordance with local electrical codes. Ensure correct DC/AC polarity, adequate wall clearance for natural cooling, and robust surge protection before powering up the system.